Make sure you have read the 1.9.1 and 1.9.2 topics before poceed.


To finalize the Format Change for the S700-WP machine you must to follow the following steps:


  1. Insert the value of the mold's heigth
  2. Insert the value of the mold's attaching plate
  3. Insert the value of the rod's heigth
  4. insert the value of the mobile mold's heigth
  5. remove the previous mold using the clamping device in the rod's end
  6. remove the previous moving mold mold using the two M8 screws in the moving mold's attaching plate
  7. remove the under mold using the clamping device in the under mold pump
  8. move the extraction sticks away form the operating zone
  9. put on the new moving mold mold using the two M8 screws in the moving mold's attaching plate
  10. put on the new mold using the clamping device in the rod's also alining it with the moving mold
  11. put on the new under mold using the clamping device in the under mold pump also alling it with the mold
  12. move the extraction sticks alining it at their hole in the mold, sure thay aren't touching the mold in all the movement
  13. if necessary replace the blades/brushes for the vertical wrap
  14. replace all the blades for the horizontal wrap, sure they are locked and alined properly, if necessary replace the blade's support with a model compatible with the format
  15. relpace all the swabs, sure they are locked and alined properly