Electric supply:


The line requires an electrical power supply of 400 V ± 10%, with a frequency of 50 Hz ± 2%, three-phase. The connection is performed individually for each S700-SP, S700-WP and S700-QS machine.

The ground connection must be properly connected to the electrical cabinet, to the appropriate earth / main terminal block having a minimum section of 10 mm2.

All electrical connections must be carried out by third level qualification staff.


Pneumatic supply:


The compressed air supply to the S700 line must be connected via the air handling unit on the S700-SP at a pressure of 5 ÷ 7 bar which can then be adjusted by means of a special regulator.
The connection to the pneumatic supply must be carried out by second level qualified operators.


LAN connection:


To operate the S700 line must have access to Internet services through its LAN port.
The connection must be made with an ethernet cable at least Category 5.
The connection to the network must be carried out by second level qualified operators.


Water supply:


To operate the S700 line must be connected to a water source with medium hardness (8 to 12 ° F hardness).
The connection to the water supply must be carried out by second level qualified operators.